VFPS1 Series
Capacity range:
3 phase 200V-0.4~90kW
3 phase 400V-0.75~630kW
3 phase 500V-1.5~500kW
3 phase 575V-2.0~700HP
3 phase 690V-2.2~630kW
3 phase 400V-0.75~90kW (IP54)
The efficiency of induction motor normally fall at the light load and low speed. The advanced energy-saving mode minimize the loss of induction motor by controlling excitation current belong to the load. Therefore, this mode increase fan and pump efficiency even in the low speed. | |
The Energy saved power consumption can be monitored by operation panel or through serial communication data. |
Built-in noise filters are ideal for site such as commercial facilities and offices where attention must be paid to peripheral devices. Compared to filter not integrated models, space and wiring can be saved by incorporating filter in the panel. Models with built-in EMC noise filter comply with the European EMC Directive as individual inverter units.
European EMC Directive :
|
200V class models, 0.4 to 7.5kW : EMI noise filter (complies with the European EMC Directive) built-in standard |
New types of compact and space-saving DC reactor is built-in for 200 V class 11 to 45 kW and 400 V 18.5 to 75 kW models. In addition to reducing harmonics, this reactor limits the input current to 110% of the rated output current, and it has been designed to be compatible with power supply systems containing transformers, molded-case circuit breakers, and power lines. Optional DC reactor meets IEC harmonics standards. |
|
|
|
|
Communications and Network
*1 DeviceNet is a registered trademarks of ODVA (Open DeviceNet Vendor Association). CC-Link is a registered trademarks of Mitsubishi Electric Corporation. LONWORKS is a registered trademark of Echelon Corporation. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers, Incorporated. Metasys N2 is a registered trademark of Johnson Controls, Incorporated. APOGEE FLN is a registered trademark of Siemens Building Technologies, Incorporated. |
|
Customizing by "My Function" Using "My function", you can create programs up to 28 steps. This achieves logic operations and internal data operations. Parameters can also be set by analog input and minimum-peak hold of analog outputs. For example: (Ex.1)Inverter is automatically switched to commercial operation without external sequence when the inverter is tripped. |
|
LCD Remote Keypad Option This panel indicates 8-line of 23 letters and can be used for simple setup and monitoring by selection of parameters using the jog dial. Type:RKP004Z |
|
LED Remote Keypad Option 20 mm LEDs, ensure outstanding visibility even in the darkness. It is designed to be mounted on the panels as extension display or remote keypad. In addition, parameter copy and storing function is also available Type:RKP002Z |
|
Expanded Terminal Block Option, Fieldbus Option I/O terminal block can be added for more complicated operation and wide range of systems: . Contact inputs (4) . Contact outputs (2) . Analog inputs (2) . Analog outputs (2) . PTC input (1) . Relay output (1 circuit) . Pulse train input (1) Type:ETB003Z, ETB004Z Main fieldbuses as built-in option card are supported for space saving and centralized control systems. . DeviceNet® . PROFIBUS . CC-Link Type:DEV002Z Type:PDP002Z Type:CCL001Z . LONWORKS® . BAC net® . Metasys®N2 Type:LIU006Z Type:BCN001Z Type:MTS001Z . APOGEE®FLN Type:APG001Z |