FRENICS-ACES

Customizable Logic

Customizable logic function is available as a standard feature. FRENIC-Ace has built-in customizable logic functions with a maximum of 200 steps including both digital and analog operation functions, giving customers the ability to customize their inverters—from simple logic functions to full-scale programming. Fuji Electric also has plans to offer programming templates for wire drawing machines, hoists, spinning machines, and other applications so that the FRENIC-Ace can be used as a dedicated purpose inverter.

Superior Flexibility

FRENIC-Ace has readily available interface cards and various types of fieldbus / network to maximize its flexibility

Option CategoryOption NameMounting adapter for option card
0002 to 0044 (400V),
0001 to 0069 (200V)
0059 to 0072 (400V),
0069 to 0115 (200V)
more than 0085 (400V)
Terminal blockRS-485 communications card Unnecessary
PG interface (5V) card
PG interface (12/15V) card
Communication *1DeviceNet communication card The adapter ismounted on thefront side of the inverter.
(OPC-E2-ADP1)
The adapter ismounted inside ofthe inverter.
(OPC-E2-ADP2)
The adapter ismounted inside ofthe inverter.
(OPC-E2-ADP3)
CC-Link communication card
PROFIBUS-DP communication card
EtherNet/IP communication card
ProfiNet-RT communication card
CANopen communication card
Input / Output interface *1Digital Input / Output interface card
Analog Output interface interface card

*1 Available by the combination use of the mounting adapter.

Wide Variety Of Functions As A Standard Feature

  • Sensorless dynamic torque vector control
  • Motor vector control with PG (with optional card)
  • Synchronous motor with sensorless vector control
  • 2-channel on-board RS485 communications port
  • Standard CANopen compatibility
  • Removable keypad device
  • Removable control terminal block board

Multi-Function Keypad (option)

FRENIC-Ace has two different multi-function keypads available

  • Multi-function keypad with LCD display: Enhanced HMI functionality
  • USB keypad: Connect to a computer for more efficient operation (set-up, troubleshooting, maintenance, etc)

Functional Safety

FRENIC-Ace is equipped with STO functional safety function as a standard. Therefore output circuit magnetic contactors are not required for safe stop implementation. Enhanced standard features position FRENIC-Ace ahead of its class (Safety input: 2CH, output: 1CH).

Complies with (coming soon)
EN ISO 13849-1: 2008, Cat.3 / PL=e
IEC/EN 60204-1: 2005/2006 Stop category 0
IEC/EN 61508-1 to -7: 2010 SIL3
 
IEC/EN 61800-5-2: 2007 SIL3 (Safety feature: STO)
IEC/EN 62061: 2005 SIL3

10 Years Lifetime Design

FRENIC-Ace components have a design life of ten years.
A longer maintenance cycle also helps to reduce running costs.

Design lifeMain circuit capacitor 10 years*
Electrolytic capacitors on PCB 10 years*
Cooling fan 10 years*
Life conditionsAmbient temperature +40°C
Load rate 100% (HHD specifications)
80% (HND/HD/ND specifications)

* ND specifications have a rated current of two sizes higher than HHD specifications, so the life is 7 years.