Powerful & Upgraded Performance
Sensorless Vector Control
- The built-in sensorless vector control provides the superb speed control and powerful high torque.
Built-in PID Control
- The built-in PID function enables to control flow-rate, oil-pressure, temperature, etc without any extra controller.
Built-in Dynamic Braking Circuit
- The built-in dynamic braking circuit minimizes deceleration time via braking resistors.
User-Friendly Interface & Easy Maintenace
iG5A is designed to be the fan changeable structure in preparation for a fan breakdown.
By controlling the cooling fan, iG5A provides a virtually quiet environment according to the status of operation.
The 4 directions key provides easy handling and monitoring.
Specification
1-phase 200V Class
SV ㅁㅁㅁ iG5A-1ㅁㅁ | 004 | 008 | 015 |
Max. Capacity 1) | [HP] |
0.5 |
1 |
2 |
[kW] |
0.4 |
0.75 |
1.5 |
Output Rating | Capacity [kVA] 2) |
0.95 |
1.9 |
3.0 |
FLA [A] 3) |
2.5 |
5 |
8 |
Max Frequency |
400 [Hz] 4) |
Max Voltage |
3 Phase 200 ~ 230V 5) |
Input Rating | Rated Voltage |
1phase 200~230 VAC (+10%, -15%) |
Rated Frequency |
50 ~ 60 [Hz] (±5%) |
Cooling Method |
Forced Air Cooling |
Weight [kg] |
0.76 |
1.12 |
1.84 |
3-phase 200V Class
SV ㅁㅁㅁ iG5A-2ㅁㅁ | 004 | 008 | 015 | 022 | 037 | 040 | 055 | 075 | 110 | 150 | 185 | 220 |
Max. Capacity 1) | [HP] |
0.5 |
1 |
2 |
3 |
5 |
5.4 |
7.5 |
10 |
15 |
20 |
25 |
30 |
[kW] |
0.4 |
0.75 |
1.5 |
2.2 |
3.7 |
4.0 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
Output Rating | Capacity [kVA] 2) |
0.95 |
1.9 |
3.0 |
4.5 |
6.1 |
6.5 |
9.1 |
12.2 |
17.5 |
22.9 |
28.2 |
33.5 |
FLA[A] 3) | 2.5 |
5 |
8 |
12 |
16 |
17 |
24 |
32 |
46 |
60 |
74 |
88 |
Max Frequency |
400 [Hz] 4) |
Max Voltage |
3 Phase 200 ~ 230V 5) |
Input Rating | Rated Voltage |
3 phase 200~230 (+10%, -15%) |
Rated Frequency |
50~60 [Hz] (±5%) |
Cooling Method |
N/C 6) |
Forced Air Cooling |
Weight [kg] |
0.76 |
0.77 |
1.12 |
1.84 |
1.89 |
1.89 |
3.66 |
3.66 |
9.0 |
9.0 |
13.3 |
13.3 |
3-phsae 400V Class
SV ㅁㅁㅁ iG5A-4ㅁㅁ | 004 | 008 | 015 | 022 | 037 | 040 | 055 | 075 | 110 | 150 | 185 | 220 |
Max. Capacity 1) | [HP] |
0.5 |
1 |
2 |
3 |
5 |
5.4 |
7.5 |
10 |
15 |
20 |
25 |
30 |
[kW] |
0.4 |
0.75 |
1.5 |
2.2 |
3.7 |
4.0 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
Output Rating | Capacity [kVA] 2) |
0.95 |
1.9 |
3.0 |
4.5 |
6.1 |
6.9 |
9.1 |
12.2 |
18.3 |
22.9 |
29.7 |
34.3 |
FLA [A] 3) |
1.25 |
2.5 |
4 |
6 |
8 |
9 |
12 |
16 |
24 |
30 |
39 |
45 |
Max Frequency |
400 [Hz] 4) |
Voltage [V] |
3 Phase 380 ~ 480V 5) |
Input Rating | Rated Voltage |
3 phase 380~480 VAC (+10%, -15%) |
Rated Frequency |
50~60 [Hz] (±5%) |
Cooling Method |
N/C 6) |
Forced Air Cooling |
Weight [kg] |
0.76 |
0.77 |
1.12 |
1.84 |
1.89 |
1.89 |
3.66 |
3.66 |
9.0 |
9.0 |
13.3 |
13.3 |
1) Indicate the maximum applicable motor capacity when using 4 pole LS standard motor.
2) Rated capacity is based on 220V for 200V series and 440V for 400V series.
3) Refer to 15-3 of userʼs manual when carrier frequency setting (39) is above 3kHz.
4) Max. frequency setting range is extended to 300Hz when H40 (Control mode select) is set to 3 (Sensorless vector control).
5) Max. output voltage cannot be higher than the input voltage. It can be programmable below input voltage.
6) Self-Cooling