iS7

Features

Powerful Performance

  • Control mode: V/F, V/F PG, Sensorless Vector, Vector
  • Speed Control Range 1:100(Sensorless Vector), 1:1000(Vector)
  • LV Trip Delay Function, Cooling Fan Control
  • Droop control, KEB Function, Flying Start, Flux Brake
  • PMSM Control

Flexibility

  • Built-in RS485 & Modbus Communication
  • Profibus-DP, DeviceNet, LonWorks, Rnet, Modbus TCP Option
  • Max. Input 11 Points, Output 6 Points when use expended I/O Card
  • PLC Card option: Master-K platform Normal Input 14 Points, Normal Output 7 points
  • Encoder Card option
  • Optional IP54 Enclosure (~ 22kW)

Convenience & Environment

  • Built-in EMC filter to protect from excessive electronic distortion
  • DC reactor built-in for harmonic reduction and power factor improvement
  • Widened graphic LCD keypad
  • Multi-language support (5 languages)
  • User & macro group support

 

Specification

 

3-phase 200V Class (0.75~22kW) 
Type: SVㅁㅁㅁㅁiS7-2ㅁ0008001500220037005500750110015001850220
Motor Applied 1)VT[HP] 2 3 5 7.5 10 15 20 25 30 40
[kW] 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30
CT[HP] 1 2 3 5 7.5 10 15 20 25 30
[kW] 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
Rated OutputRated Capacity [kVA] 2) 1.9 3.0 4.5 6.1 9.1 12.2 17.5 22.9 28.2 33.5
Rated Current [A] 3)CT 5 8 12 16 24 32 46 60 74 88
VT 8 12 16 24 32 46 60 74 88 124
Output Frequency [Hz] 0~400 [Hz] 4)
Output Voltage [V] 3-phase 200 ~ 230V 5) (Sensorless-1 : 0~300Hz, Sensorless-2, Vector : 0.1~120Hz)
Rated InputAvailable Voltage [V] 3-phase 200 ~ 230 VAC (-15% ~ +10%)
Frepuency [Hz] 50 ~ 60 [Hz] (±5%)
Rated Current [A]CT 4.3 6.9 11.2 14.9 22.1 28.6 44.3 55.9 70.8 85.3
VT 6.8 10.6 14.9 21.3 28.6 41.2 54.7 69.7 82.9 116.1

 

 

3-phase 200V Class (30~375kW) 
Type: SVㅁㅁㅁㅁ iS7-2ㅁ03000370045005500750-----
Motor Applied 1)VT[HP] 50 60 75 100 125 - - - - -
[kW] 37 45 55 75 90 - - - - -
CT[HP] 40 50 60 75 100 - - - - -
[kW] 30 37 45 55 75 - - - - -
Rated OutputRated Capacity [kVA] 2) 46 57 69 84 116 - - - - -
Rated Current [A] 3)CT 116 146 180 220 288 - - - - -
VT 146 180 220 288 345 - - - - -
Output Frequency 0 ~ 400 [Hz] (Sensorless-1: 0 ~ 300Hz, Sensorless-2, Vector: 0 ~ 120Hz) 4)
Output Voltage [V] 3-phase 200 ~ 230V 5)
Rated InputAvailable Voltage [V] 3-phase 200 ~ 230VAC (-15% ~ +10%)
Frepuency [Hz] 50 ~ 60 [Hz] (±5%)
Rated Current [A]CT 121 154/td> 191 233 305 - - - - -
VT 152 190 231 302 362 - - - - -

 

 

3-phsae 400V Class (0.75~22kW) 
Type: SVㅁㅁㅁㅁ iS7-4ㅁ0008001500220037005500750110015001850220
Motor Applied 1)VT[HP] 2 3 5 7.5 10 15 20 25 30 40
[kW] 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30
CT[HP] 1 2 3 5 7.5 10 15 20 25 30
[kW] 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
Rated OutputRated Capacity [kVA] 2) 1.9 3.0 4.5 6.1 9.1 12.2 17.5 22.9 29.7 34.3
Rated Current [A] 3)CT 2.5 4 6 8 12 16 24 30 39 45
VT 4 6 8 12 16 24 30 39 45 61
Output Frequency 0~400 [Hz] 4)
Output Voltage [V] 3-phase 380 ~ 480V 5) (Sensorless-1 : 0~300Hz, Sensorless-2, Vector : 0.1~120Hz)
Rated InputAvailable Voltage [V] 3-phase 380 ~ 480 VAC (-15% ~ +10%)
Frepuency [Hz] 50 ~ 60 [Hz] (±5%)
Rated Current [A]CT 2.2 3.6 5.5 7.5 11.0 14.4 22.0 26.6 35.6 41.6
VT 3.7 5.7 7.7 11.1 14.7 21.9 26.4 35.5 41.1 55.7

 

 

3-phase 400V Class (30~375kW) 
Type: SVㅁㅁㅁㅁ iS7-2ㅁ03000370045005500750090011001320160018502200285031503750
Motor Applied 1)VT[HP] 50 60 75 100 125 150 200 250 300 350 400 500 600 700
[kW] 37 45 55 75 90 110 132 160 185 220 280 315 375 450
CT[HP] 40 50 60 75 100 125 150 200 250 300 350 400 500 600
[kW] 30 37 45 55 75 90 110 132 160 185 220 280 315 375
Rated OutputRated Capacity [kVA] 2) 46 57 69 84 116 139 170 20 248 286 329 416 467 557
Rated Current [A] 3)CT 61 75 91 110 152 183 223 264 325 370 432 547 613 731
VT 75 91 110 152 183 223 264 325 370 432 547 613 731 877
Output Frequency 0 ~ 400 [Hz] (Sensorless-1: 0 ~ 300Hz, Sensorless-2, Vector: 0 ~ 120Hz) 4)
Output Voltage [V] 3-phase 380 ~ 480V 5)
Rated InputAvailable Voltage [V] 3-phase 380 ~ 480 VAC (-15% ~ +10%)
Frepuency [Hz] 50 ~ 60 [Hz] (±5%)
Rated Current [A]CT 55.5 67.9 82.4 102.6 143.4 174.7 213.5 255.6 316.3 404 466 605 674 798
VT 67.5 81.7 101.8 143.6 173.4 212.9 254.2 315.3 359.3 463 590 673 796 948

 



1) Motor Applied indicates the maximum capacity applied to use of a standard 4 pole standard motor.

2) Rated Capacity: the input capacity of a 200V class is based on 220V and that of a 400V class is based on 440V. The current rating is based on CT current.

3) The output of rated current is limited according to the setting of the carrier frequency (CON-04).

4) You can set the frequency at up to 300Hz by selecting 3, 4 Sensorless-1, Sensorless-2 as the control mode (DRV-09 Control Mode).

5) The maximum output voltage does not go over the supplied power voltage. You can select the output voltage as you want below the supplied power voltage.

* Non DCR products are provided warranty service when used in CT (Heavy duty) load rating only.